Mississippi State University 2006
From 2006.igem.org
(Difference between revisions)
Line 98: | Line 98: | ||
* BBa_J43000 was a failed part, we learned during completion of the construction and testing that there was a flaw in the design of the composite part. Although the hybB promoter does appear to detect hydrogen, the YFP is inhibited with the addition of tetR. Therefore, we cannot detect a change in fluorescence when hydrogen is added. | * BBa_J43000 was a failed part, we learned during completion of the construction and testing that there was a flaw in the design of the composite part. Although the hybB promoter does appear to detect hydrogen, the YFP is inhibited with the addition of tetR. Therefore, we cannot detect a change in fluorescence when hydrogen is added. | ||
- | * For the BBa_J43001, | + | * For the BBa_J43001, calculated error provides a possible explaination for why 100% hydrogen concentration fluoresced more than 75% hydrogen concentration. More testing required to determine the 100% hydrogen result. |
Latest revision as of 19:33, 30 October 2006
The TeamFaculty Members:
Students:
|
Introduction
|
H2 Reporter
|
Results
|
Discussion
|
Accomplishments
|