ETH Zurich 2006

From 2006.igem.org

(Difference between revisions)
Jump to: navigation, search
m (Modeling)
(Documentation)
Line 40: Line 40:
*Make a drawing of the DNA to have an overview of which parts will be consecutively on the same DNA piece (Alexandra)
*Make a drawing of the DNA to have an overview of which parts will be consecutively on the same DNA piece (Alexandra)
*Find promoters for the Pops duplexer (2 promoters in total) (Michael)
*Find promoters for the Pops duplexer (2 promoters in total) (Michael)
 +
* make poster for jamboree (who?)
==== Presentation and PR====
==== Presentation and PR====

Revision as of 14:03, 12 October 2006

ETH Team 2006


standing (L-R): Marco, Alexandra, Arthur, Olga, Dimo, Marko, Robert; in front (L-R):

Franz, Michael



Adding numbers is easy, isn't it? 1234 plus 5678, for example, is 6912. But how do engineers add binary numbers instead of decimal ones? And how, in the end, can this be done by a living cell? We, the members of the ETH Zurich 2006 iGEM team, are currently working on these questions, whereas the last one seems to be not trivial.

What the addition of numbers has to do with pattern recognition, how our model and the mathematical analysis look like, and how the experiments are realized will be explained on these wiki pages. We wish you a pleasant time with our pages. Enjoy it!



Contents

Coordination

TODOs

Modeling

  • Parts Model the whole System with Sensing, Pops duplexer and Half adder (Marco and Franz)
  • Model whether a different strength of input is necessary for the AND and XOR Gates (Who?)
  • Finish modeling the second AND Gate and find a biological way to implement it and write the DNA and order it (Marco and Robert)

Lab

Responsible: Robert for the preparatory experiments, Olga for the assembly and testing of the gates.

  • Read the literature on the XOR and AND Gates, check carefully for strains needed and compatibility of the parts (Who?)
  • Prepare a protocol for parts assembly (Olga)
  • Assembly of the light sensing device from the parts we received from UCSF Voigt's lab (Arthur)
  • Assembly of the chemical sensing device (Franz, Dimo, Robert, Marco, Marko, Olga)

Documentation

Responsible: Alexandra for the registry, Arthur for the Wiki.

  • enter lab experience report to registry
  • Make a picture of the whole model with te different parts in it (Alexandra)
  • Make a drawing of the DNA to have an overview of which parts will be consecutively on the same DNA piece (Alexandra)
  • Find promoters for the Pops duplexer (2 promoters in total) (Michael)
  • make poster for jamboree (who?)

Presentation and PR

Responsible: Franz for the presentation, Dimo for PR

  • choose two or maximum three speakers who will present our work at the jamboree
  • design and write the final presentation (with LaTex beamer class?)
  • draw a team logo and find a team name
  • design and order T-Shirts


Schedule

Available as Google Calendar: [http://www.google.com/calendar/render?cid=pqi8ni6gnfj5r3o0np0h4smrr4@group.calendar.google.com iGEM 2006 ETH Zurich]

Thu 20.7., 1700: kickoff meeting in CNB E 121
27.7.-3.8. 1st group phase
Define project in more detail within two groups
Thu 27.7., 1700: meeting of entire group to share ideas
Thu 3.8., 1700: decision on final project
15.8. 1700
Tutorial "Modelling of AND gate"
Until 20.8.
Finalize DNA design, order it
September,October
Implement design (registry bio-bricks, ordered DNA)
27.9.
Fix the flight dates and send the proposed flights to Jörg
23.10.
Latest point to start getting our presentation going and to finish the iGEM wiki documentation
30.10.
Project documentation on the Wiki has to be complete
4./5.11.
Jamboree in Boston

Participants and availability


finding a project

Initial project ideas

The fruits of some brainstorming and research

proposed projects

We split up the whole team into two groups, each proposed a project after these two weeks.

It was decided to further pursue the Half adder project idea.

design process

This could be documented as a hierarchy of global specification -> structural specification steps (ie after-the-book engineering process). Even if nobody had that in mind probably we can mold wathever actually happened into this pattern.

system level

system behavorial specification

  1. Write something with a chemical on a petri plate (like ETH for example)
  2. Let Bacteria grow uniformly on the plate
  3. Expose the plate to a picture (black and white) of the same pattern
  4. Result:
    • Bacteria gets green when pattern on the plate and picture match (light and chemical)
    • Bacteria does not express fluorescent protein when pattern on the plate and picture match (no light and no chemical)
    • Bacteria gets red when pattern on the plate and picture do not match
           light   no light
chemical     A         B
no chemical  B         C

The outputs can be reported by fluorescent proteins, the mapping of states to outputs is arbitary, our choice is:

A: green
B: red
C: no fluorescence

Considering the green and the red output as being separate, the logic mapping the input states to the output states is AND for the GFP and XOR for the RFP. Together they amount to a half adder logic.

The whole system is only considered at it's steady state, dynamic processes are only of minor interest.

system structure

The whole process can be brought into a common input, logic, output form:

[light sensing]----->[       ]-->[reporter A]
                     [ logic ]
[chemical sensing]-->[       ]-->[reporter B]

system deployment

distribution on the plasmids, strains

system assembly procedure

system test procedure

system test results

device level

chemical sensing device

The chemical sensing device's PoPs output activity should be a monotonic function of the concentration of a certain substance in the cell's environment.

implementation alternatives
  1. Lactate lacI represses, IPTG induces ([http://partsregistry.org/Part:BBa_R0011 BBa_R0011] or [http://partsregistry.org/Part:BBa_R0010 BBa_R0010] )
  2. Tetracycline, TetR inhibitor, Tet inducer by inhibiting TetR (or aTc, it's analog) ([http://partsregistry.org/Part:BBa_R0040 BBa_R0040])
  3. combination thereof ([http://partsregistry.org/Part:BBa_I13614 BBa_I13614] / [http://partsregistry.org/Part:BBa_I13617 BBa_13617] / [http://partsregistry.org/Part:BBa_I13623 BBa_I13623] / [http://partsregistry.org/Part:BBa_I13624 BBa_I13624] / [http://partsregistry.org/Part:BBa_I13627 BBa_I13627] / [http://partsregistry.org/Part:BBa_I13637 BBa_I13637] / [http://partsregistry.org/Part:BBa_I13653 BBa_I13653])
  4. simple sugar Arabinose ([http://partsregistry.org/Part:BBa_R0080 BBa_R0080])

I see the main difficulty in the spatial separation as the cells are growing in the petri dishes. since the inducers are water-soluble we would have to fix the chemicals onto the petri dish.

complete system based on alternative 1
assembly procedure

where we got it and link to theyer documentation

Progress:

2006/10/03
Made LB-Agar plates with antibiotics
2006/10/04
Transformed cells, plated them
2006/10/05
Found plates empty after 18h on the table, put into incubator at 37°C
2006/10/06
picked cultures onto fresh plates
test procedure
test results

light sensing device

The light sensing device's PoPs output activity should be a monotonic function of the light intensity the cell is subjected to.

implementation alternatives

show how the existing light sensing device fullfills our specifications

ETH light sensing parts.png
assembly procedure

where we got it and link to theyer documentation

test procedure
test results

logic (half adder) device

Registry: [http://partsregistry.org/Part:BBa_J34000 BBa_J34000]

As stated in the #system behavorial specification the logic is made up of one AND and one XOR gate, which are each another device, plus two copy devices to replicate the inputs:

       [          ]------>[     ]
A >----[ 1:2 copy ]       [ AND ]----> X
       [          ]--, ,->[     ]
                      X
       [          ]--' '->[     ]
B >----[ 1:2 copy ]       [ XOR ]----> Y
       [          ]------>[     ]

reporters

ETH reporter.png

XOR gate

The XOR gate's PoPs output activity should be correlated to the PoPs input activity as shown in the picture:

 input A ^
         | H  D  L
         | D  D  D
         | L  D  H
         +--------->
            input B

 output: High, Low, Dont care
implementation alternatives

Part to be used in the prototype system: [http://partsregistry.org/Part:BBa_J34200 BBa_J34200]

ETH xor.png
modeling
assembly procedure
test procedure
test results

AND gate

The AND gate's PoPs output activity should be correlated to the PoPs input activity as shown in the picture:

 input A ^
         | L  D  H
         | D  D  D
         | L  D  L
         +--------->
            input B

 output: High, Low, Dont care
implementation alternatives

Part to be used in the prototype system: [http://partsregistry.org/Part:BBa_J34100 BBa_J34100]

ETH and trna parts.png
modeling
assembly procedure
test procedure
test results

PoPs duplexer device

This device has two PoPs outputs which should in terms of activity be copies of the input.

implementation alternatives
ETH duplexer a1.png
ETH duplexer a2.png
ETH duplexer a3.png
modeling
assembly procedure
test procedure
test results

parts level

for every part we use:

  • DNA sequence
  • where we got it from

(links to the registry)

Maybe this could mostly be a hierarchy of links to the registry because it's preferable to have as much documentation in the registry as possible anyway. This is nice because it emphases our incredibly systematic engineering approach and documents the processes too which could also serve for coordination of the work in progress.



modeling

The contents of this section should be placed at the appropriate places in the design process section above and the rest moved to an external page.

Matlab scripts for ODE simulation

modular scripts
  • contains a createXXX() script for each module. the created module contains
    • function handles for reaction rates: r
    • stoichiometric matrix: N
    • constants (inside of the function handles)
    • state (concentration) changes (the ode dy values) can be computed by: N · r
  • modules can be connected using the createInOutConnector() script. the result is again a module, consisting of the connected basic modules.
  • sim_1_1 and sim_1_2 can be used to simulate modules with 1 input/1 output and 1 input/2 outputs respectively.
  • both basic modules and compound (connected) modules can be simulated
  • simulations contains the first samples, simulating
  • scripts: [http://csb.inf.ethz.ch/igem-2006/matlab_modules.zip matlab_modules.zip] (<0.1M)
old scripts

unzip the file, each zip file contains 2 files: sim_xxx.m and ode_xxx.m.

ode_xxx.m : contains the differential equations, i.e. the model
sim_xxx.m : sets the parameters, calls the simulator and plots the result (this is the one to run, but the other is also needed).
  • [http://csb.inf.ethz.ch/igem-2006/matlab_sim_and1.zip matlab_sim_and1.zip] (<0.1M) →simulation resultsabandoned
  • [http://csb.inf.ethz.ch/igem-2006/matlab_sim_and2.zip matlab_sim_and2.zip] (<0.1M) →simulation results → the pursued version A
  • [http://csb.inf.ethz.ch/igem-2006/matlab_sim_and3.zip matlab_sim_and3.zip] (<0.1M) →simulation results → the pursued version B
  • [http://csb.inf.ethz.ch/igem-2006/matlab_sim_and4.zip matlab_sim_and4.zip] (<0.1M) →simulation resultsabandoned

As a result of the meeting on August 17, we will from now on concentrate on the AND versions 2 and 3.

  • [http://csb.inf.ethz.ch/igem-2006/matlab_sim_xor1.zip matlab_sim_xor1.zip] (<0.1M) →simulation results → the only pursued version
  • [http://www.tik.ee.ethz.ch/~brockho/igem2006/matlab_sim_xor2.zip matlab_sim_xor2.zip] (<0.1M) →simulation resultsabandoned
  • [http://www.tik.ee.ethz.ch/~brockho/igem2006/matlab_sim_xor3.zip matlab_sim_xor3.zip] (<0.1M) →simulation resultsabandoned

Sensoring

  • [http://csb.inf.ethz.ch/igem-2006/matlab_sim_iptg.zip matlab_sim_iptg.zip] (<0.2M) →simulation results

Useful Documents & Links

see here

Personal tools
Past/present/future years