EdinburghModeling

From 2006.igem.org

Revision as of 12:06, 29 October 2006 by Caiyizhi (Talk | contribs)
Jump to: navigation, search

Contents

System Diagram of Arsenic Biosensor([http://2006.igem.org/Image:Modeling_the_Arsenic_Biosensor_System.pdf PDF version])

Model Diagram2.JPG

Abstract

This section reports the modeling progress of an arsenic biosensor system, which is the iGEM project accomplished in the University of Edinburgh 2006. The arsenic biosensor system sought to address the fatal water pollution problem occurring in many poor countries/areas like Bangladesh by producing a calibratable pH changes in response to a range of arsenic concentrations. A computational model which contains 3 operons, 19 reactions and 17 species has been constructed to shed light on the wet-lab experimental design. By analyzing the sensitivity of each parameter/species, we identified their relative importance in the system which gives the theoretical guide when measuring the variable in wet-lab. The next step research is to refine the model by comparing it with the biological output.

Reaction set

No. Name Equation Rate Law Parameters
1 ArsD binding to Arsenic (III) ArsD+2As(III)=ArsD-2As(III)Mass Action K1=1000 K-1=0.65
2 ArsD binding to promoter1 2 ArsD+promoter1=2ArsD-promoter1 Mass ActionK2=10000, K-2=0.65
3 ArsD degradation ArsD->null Mass ActionK3=0.05
4 ArsD production promoter1->promoter1+ArsDMichaelis-Menten V4m=0.5, K4m=75
5 ArsR binding to Arsenic (III) ArsR+2As(III)=ArsR-2As(III) Mass Action K5=1000, K-5=0.65
6 ArsR binding to promoter2 2ArsR+promoter2=2ArsR-promoter2 Mass Action K6=10000, K-6=0.65
7 ArsR degradation ArsR->null Mass Action K7=0.05
8 ArsR production promoter2->promoter2+ArsR Michaelis-Menten V8m=10, K8m=25
9 LacI binding to allolactose LacI+allolactose=LacI-allolactose Mass Action K9=10000, K-9=0.1
10 LacI binding to promoter4 LacI+promoter4 = LacI-promoter4 Mass Action K10=1000, K-10=0.5
11 LacI degradation LacI->null Mass Action K11=0.1
12 LacI production promoter3->promoter3+LacI Michaelis-Menten V12m=0.5, K12m=40
13 lacZ degradation lacZ->null Mass Action K13=0.1
14 lacZ production promoter1->promoter1+lacZ Michaelis-Menten V14m=25, K14m=10
15 LCI binding to promoter 4 LCI+promoter4=LCI-promoter4 Mass Action K15=10000, K-15=0.5
16 LCI degradation LCI->null Mass Action K16=0.1
17 LCI production promoter2->promoter2+LCI Michaelis-Menten V17m=10, K17m=25
18 Urease degradation Urease->null Mass Action K18=0.1
19 Urease production promoter4->promoter4+Urease Michaelis-Menten V19m=10, K19m=40

Note: The units for first, second and third order rate constants are expressed in units of second^-1, nMol^-1*second^-1 and nMol^-2*second^-1 respectively.

Reaction Map.JPG

This reaction map is generated from the reaction set above using Simbiology Toolbox.

Initial concentration

No. Species Intial Concentration (nMol)
1 ArsD 25
2 As(III) 40
3 2ArsD-promoter1 25
4 promoter1 5
5 ArsR 25
6 2ArsR-promoter2 25
7 promoter2 5
8 LCI 4
9 LacI 0.1
10 LacI-allolactose 0.1
11 allolactose 1000
12 LacI-promoter4 0.1
13 promoter4 25
14 LCI-promoter4 0.1
15 Urease 0.1
16 promoter3 5
17 Other species 0

Ordinary Differential Equation

EdinOde1.JPG EdinOde2.JPG

Methodology

The gene expression reactions are modeled using Michaelis-Menten equation while the other reactions are described in Mass-Action equations.

We divided the whole system into three operons, namely Urease operon, LambdaCI operon and LacZ operon.

The Urease operon: 200pix

Software used

In order to model the quantitative behaviour of the dynamic system, many modeling software systems have been developed in the past few years. In this project, three kinds of software systems are used for modelling. This section introduces their functions and features.

1.System biology toolbox for Matlab: SimBiology toolbox provides functions for modelling, simulating, and analysing biochemical pathways on basis of the powerful computing engine of Matlab. Aside from the conventional typing reaction equation, SimBiology provides a user-friendly ‘dragging-and-dropping’ block diagram editor to build a new model. Thanks to the powerful computing ability of Matlab, SimBiology integrates a wide range of numerical solvers for both stochastic and deterministic simulations. Another strength of SimBiology is its analysing ability which includes sensitivity analysis, parameter estimation and conservation of moieties. Last but not the least, SimBiology provides user-defined plotting function which was widely used in this research project. However SimBiology is commercial software, it costs the budgeted researchers extra expense to purchase the license for this toolbox. Also, there is no GUI for sensitivity analysis and parameters scan functions, so users should obtain the skill of programming with Matlab.

2.BIOCHAM: BIOCHAM stands for biochemical abstract machine which is a formal modeling environment for system biology. Because of its rule-based language and temporal logic based language, BIOCHAM can offer an automatically reasoning tool for querying the temporal properties of the system under all its possible behaviours. It is very useful for constructing models especially when numerical data is unavailable. BIOCHAM also provides a state-of-the-art symbolic model checker for handling the complexity of large highly non-deterministic models. Furthermore, it provides simulation results via its graphical interface. One disadvantage of BIOCHAM is that because it is initially developed under UNIX, it uses command line rather than GUI to build new models, requiring users to write scripts by hand. Another problem was that when transplanting the program from UNIX to Windows, the model checker of NuSMV does not work well. So this project used BIOCHAM in Fedora 5 rather than Windows XP.

3. COPASI: COPASI is freeware developed with collaboration of VBI and EMLR. It provides almost the same functions as SimBiology, though not quite powerful. But compared with SimBiology, it provides a friendly user interface for model analysis, such as parameter estimation, and parameter scan. But there is no parameters/species sensitivity analysis function in COPASI, and also it is not very stable in use, crashing without any responses.

To sum up, each software has its own pros and cons. A good strategy is to apply them for different purposes, for example, using SimBiology to analyze the sensitivity of the model, and using COPASI to scan the most sensitive parameters. When logical queries are needed, BIOCHAM should be the first choice. SimBiology is suitable for generating professional plots, however due to the license requirement, COPASI can be the alternative choice to to run simulations and export the results to such plotting software as SigmaPlot.

Results

System response

Fig.1 System response with 5ppb arsenic input
Fig.2 System response with 20ppb arsenic input

Parameter sensitivity analysis

Fig.3 Sensitivity of lacZ with Respect to Model Parameters 1-16
Fig.4 Sensitivity of lacZ with Respect to Model Parameters 17-32

The most sensitive parameters affecting lacZ

Nanme Description Peak value of sensitivity Normal value
K-1 ArsD-2AS(III) dissociate rate -20.65/s
K-2 2ArsD-promoter1 dissociate rate 4 0.65/s
K3 ArsD degradation rate 90 0.05/s
K7 ArsR degradation rate 12 0.05/s
K13 LacZ degradation rate -35 0.1/s


Fig.5 Varying the Value of Parameter K-1 effect on lacZ
Fig.5 Varying the Value of Parameter K-1 effect on lacZ (3D)
Fig.5 Varying the Value of Parameter K-2 effect on lacZ


Fig.5 Varying the Value of Parameter K3 effect on lacZ
Fig.5 Varying the Value of Parameter K7 effect on lacZ
Fig.5 Varying the Value of Parameter K13 effect on lacZ
Fig.5 Sensitivity of Urease with Respect to Model Parameters 1-16
Fig.6 Sensitivity of Urease with Respect to Model Parameters 17-32

The most sensitive parameters affecting Urease

Nanme Description Peak value of sensitivity Normal value
k3 ArsD degradation rate -300.05/s
k-6 2ArsR-promoter2 dissociate rate -5 0.65/s
k7 ArsR degradation rate -120 0.05/s
K18 Urease degradation rate -350 0.1/s
V19m Urease production maxium rate 3.5 10 nMol/s
Fig.5 Varying the Value of Parameter K3 effect on Urease
Fig.5 Varying the Value of Parameter K-6 effect on Urease
Fig.5 Varying the Value of Parameter K7 effect on Urease
Fig.5 Varying the Value of Parameter K18 effect on Urease

Species sensitivity analysis

Fig.7 Sensitivity of lacZ with Respect to Model Species

The most sensitive species affecting lacZ

NameInitial concentration (nMol)
promoter1 5.0
promoter2 5.0
ArsD-2As(III) 0
ArsD 25
ArsR 25
Fig.7 Varying the Value of Species promoter1 Effect on lacZ
Fig.7 Varying the Value of Species promoter2 Effect on lacZ
Fig.7 Varying the Value of Species ArsD-2As(III) Effect on lacZ
Fig.7 Varying the Value of Species ArsD Effect on lacZ


Fig.7 Varying the Value of Species ArsR Effect on lacZ


Fig.8 Sensitivity of Urease with Respect to Model Species

The most sensitive species affecting Urease

NameInitial concentration (nMol)
LCI 4
LacI-promoter4 0.1
promoter4 25
promoter2 5
promoter1 5
Fig.7 Varying the Value of Species LCI Effect on Urease
Fig.7 Varying the Value of Species LacI-promoter4 Effect on Urease


Fig.7 Varying the Value of Species promoter4 Effect on Urease
Fig.7 Varying the Value of Species promoter2 Effect on Urease
Personal tools
Past/present/future years